How Do I Turn Off Auxiliary Heat on a Honeywell Thermostat?

To turn off auxiliary heat on a Honeywell thermostat, open the System menu and pick Heat or Off instead of Emergency Heat. Some models also let you limit or lock out auxiliary stages in the installer setup menu. Menu names differ by model, so check the manual for your exact model number.

What is the difference between auxiliary heat and emergency heat?

Auxiliary heat is backup heat, usually electric strips, that a heat pump calls on automatically when it cannot keep up. Emergency heat is a manual setting that shuts off the heat pump and runs only the backup source. One happens on its own, while the other only runs when you select it.

Auxiliary heat shows up during defrost cycles, after big temperature setbacks and on the coldest mornings. Short bursts are normal. Most West Valley winters are mild, so a system that leans on aux heat for long stretches often has something wrong.

Emergency heat is meant for a heat pump that has failed outright. If it stays selected, the compressor never helps and the electric strips carry the entire load, which is the most expensive way to heat a home.

Nothing here replaces the manual. Honeywell lists menu paths by model number, and a few models hide installer settings behind a short button hold. Take a photo of each screen before changing a setting so you can return to it.

Why does my aux heat keep running in mild Arizona weather?

Aux heat that keeps running in mild Arizona weather usually means the heat pump is not producing enough heat by itself. Typical causes include a clogged filter, a refrigerant leak, an iced outdoor coil, a weak outdoor fan or compressor, or a thermostat asking for a large temperature jump all at once.

Start with what is safe to check. Replace a dirty filter, make sure supply vents are open, and look at the outdoor unit for ice or debris blocking airflow. Raising the setpoint a degree or two at a time also keeps the system from calling for backup heat.

If the filter is clean and aux heat still runs most of the day, the problem is inside the system. Refrigerant work, fan motors and compressor diagnosis belong to a licensed technician.

Cold mornings in Peoria or Surprise can briefly trigger aux heat after an overnight setback. A smaller setback, a degree or two, lets the heat pump recover without calling for strips.

Can I change the auxiliary heat lockout or stage settings?

Many Honeywell models let you change them in the installer setup menu, where the heat pump can be set to lock out backup heat above a chosen outdoor temperature or to wait before staging it on. Available options depend on the model, and a wrong value can leave the house cold.

Installer menus are usually reached by holding a button combination found in the manual. Write down the original value before changing anything so you can restore it.

Some thermostats cannot see an outdoor temperature at all, so a lockout setting may do nothing. A technician can confirm the thermostat is wired and configured for your equipment, which matters more than any single menu option.

Document what you changed. If a technician visits later, a list of your thermostat settings saves time and keeps them from chasing a problem you created by accident.

Is it safe to turn off backup heat completely?

Turning backup heat off completely is safe only if the heat pump can heat your home alone on the coldest days it will face. In most of the Phoenix area that is often true, but it should be a deliberate choice rather than a fix for a system that keeps calling for backup.

Disabling backup heat hides a symptom. If the electric strips keep switching on, the heat pump is telling you it cannot keep up, and silencing it leaves you with a cold house and a problem that keeps growing.

If you see sparks, smell burning near the air handler, or a breaker keeps tripping when the strips run, turn the system off at the thermostat and call a licensed electrician or technician. Vortech's licensed AC technicians can test the heat pump and the thermostat wiring together when aux heat will not quit.

More questions: Thermostats: 12 Most Asked Questions Answered

Related Services

Service Areas

Frequently Asked Questions

Why does my Honeywell thermostat say Aux Heat on?

A Honeywell thermostat shows Aux Heat when it is running the backup heat source alongside or instead of the heat pump. That usually happens during defrost, when the room is far below the setpoint, or when the heat pump cannot keep up with the demand.

Will turning off aux heat lower my electric bill?

Turning off aux heat can lower your electric bill, because electric strips use far more power than a working heat pump. The savings only hold if the heat pump can warm the house alone, so a system that still needs backup will simply run longer and feel colder.

Can a new thermostat fix constant auxiliary heat?

A new thermostat fixes constant auxiliary heat only if the old one was misconfigured, miswired or failing. If the heat pump itself is weak, the new thermostat will still call for backup. A technician can tell which one you have by testing the system and the wiring.